Reading Peptide Receptor Assays: Kd, Ki, IC50 and EC50

Papers on receptor-active peptides report Kd, Ki, IC50 and EC50 values, often side by side, but they come from different experiments. This guide explains what each one measures, how they are related, worked conversions, and why one peptide can give different values in different laboratories.

General laboratory-science education. Not medical advice. Sealed Peptides materials are for in-vitro and laboratory research use only, and are not for human or veterinary use.

Two kinds of experiment, four numbers

Studies of receptor-active peptides usually report two kinds of measurement. Binding experiments ask how tightly a peptide occupies a receptor and give a dissociation constant (Kd), or an inhibition constant (Ki) for an unlabelled competitor. Functional experiments ask how much of a cellular response a peptide produces at each concentration and give an EC50 (potency) and a maximal effect, Emax. The IC50 sits between them: it is the concentration that reduces a signal by half, and it can come from either kind of assay.

Pharmacology has standard definitions and symbols for these quantities, set out by the international committee on receptor nomenclature.[1]

Saturation binding and Kd

At equilibrium, simple binding follows the law of mass action. The fraction of receptors occupied is [L] / ([L] + Kd), where [L] is the free ligand concentration. Kd is therefore the concentration at which half the receptors are occupied, and lower Kd means tighter binding.

A worked example: for a peptide with a Kd of 2 nM, 0.2 nM occupies about 9% of receptors, 2 nM occupies 50% and 18 nM occupies 90%. Going from 10% to 90% occupancy needs an 81-fold range, which is why curves use a log axis and a serial dilution across several orders of magnitude.

Two design errors distort Kd. If the receptor binds a large share of the added ligand, the free concentration is lower than the nominal one (ligand depletion); and if incubation is too short, the measurement is taken before equilibrium. Reviews of equilibrium binding methods describe how to detect and correct both, and note that buffer composition and temperature also change measured affinities.[2] A practical essay on binding assays makes the same points: vary the concentration of one partner across a range around the Kd, and show by a time course that binding has reached equilibrium.[3]

Competition binding: from IC50 to Ki

Many peptides have no labelled version of their own, so a fixed concentration of a labelled tracer is mixed with increasing concentrations of the unlabelled peptide. The IC50 is the concentration that displaces half the specific tracer binding. Because more tracer needs more competitor to displace it, the IC50 depends on the tracer concentration and is not a constant of the peptide.

For competitive binding, the Cheng-Prusoff relationship converts IC50 into Ki, the equilibrium constant of the competitor: Ki = IC50 / (1 + [L]/Kd), where [L] is the tracer concentration and Kd its dissociation constant.[4]

A worked example: tracer at 0.5 nM with a Kd of 0.25 nM, and a measured IC50 of 30 nM, gives Ki = 30 / (1 + 2) = 10 nM. Run the same peptide with tracer at 0.025 nM and the IC50 would be about 11 nM; at 1 nM it would be about 50 nM. Ki, not IC50, is the number to compare. The correction assumes equilibrium, no ligand depletion and a competitive mechanism; the review cited above describes an extension of the assay that can show whether an interaction is competitive or allosteric.[2]

Functional assays: EC50, Emax and the curve fit

In a functional assay, cells expressing the receptor are exposed to a concentration series and a response such as cAMP, calcium or beta-arrestin recruitment is measured. The data are usually fitted with a four-parameter logistic equation: a bottom plateau, a top plateau (Emax), a midpoint and a slope (Hill coefficient).

Guidelines for EC50 and IC50 estimation distinguish the relative value, the midpoint between the fitted plateaus, from the absolute value, the concentration that gives 50% of the control response. A relative value is reportable only when at least two tested concentrations lie beyond each bend of the curve, and an absolute value only when at least two predicted responses fall on each side of 50%.[5] A curve that never levels off at the top gives an unreliable midpoint.

Why EC50 is not the same as Kd

A functional response passes through a chain of amplifying steps. The operational model of agonism describes this with an affinity constant (KA), the receptor concentration and a transducer ratio, tau, that captures how efficiently occupied receptors produce a response.[6] For the simplest form of the model, EC50 = KA / (1 + tau). With tau = 9, the EC50 is one tenth of the KA: half the maximal response is reached when only about 10% of receptors are occupied.

The consequence is that EC50 depends on the cell system. The same peptide can look more potent in a cell line with high receptor expression or with a strongly amplified readout such as cAMP, and less potent in a weakly amplified readout. Potency comparisons are most meaningful side by side in the same assay.

Log units and averaging

Potency spans orders of magnitude, so values are often given as pEC50 or pKi, the negative base-10 logarithm of the molar value.[1] 1 nM is a pEC50 of 9.0, 3 nM is 8.52 and 30 nM is 7.52; one log unit is a ten-fold difference.

Replicate experiments are averaged on the log scale. EC50 values of 1 nM and 10 nM have an arithmetic mean of 5.5 nM, but a mean pEC50 of 8.5, which corresponds to 3.2 nM (the geometric mean).

Peptide-specific pitfalls

Most errors in peptide potency data come from the actual concentration differing from the nominal one:

  • Net peptide content. A stock made from weighed powder includes water and counter-ions. If the powder is 75% peptide by mass, every concentration is 25% lower than calculated and the reported EC50 is about 1.33-fold too high (0.12 log units). See purity versus net peptide content.
  • Adsorption at low concentration. At picomolar to low nanomolar levels a large share of a peptide can be lost to plastic and glass, distorting the low end of the curve. See the labware adsorption guide; a carrier protein in the assay buffer is a common countermeasure.
  • Buffer and albumin. Buffer composition and temperature change measured affinities.[2] Peptides with a fatty-acid side chain, a design that promotes albumin binding, can appear less potent as the albumin content of the buffer rises, so the albumin or serum concentration belongs in the method.
  • Stability during incubation. Proteases from cells or serum can degrade a peptide during long incubations. See stability in serum and plasma.

One peptide, several receptors and pathways

Multi-receptor peptides add another layer. A pharmacology study of Tirzepatide measured binding and signalling at the GIP and GLP-1 receptors and reported that it behaved like native GIP at the GIP receptor, while at the GLP-1 receptor it favoured cAMP generation over beta-arrestin recruitment and drove less receptor internalization than GLP-1.[7] A single EC50 per receptor would miss this pathway difference, described as biased agonism. The same questions apply to Retatrutide, studied at three receptors, and to single-receptor peptides such as Kisspeptin-10.

A record checklist

For a binding or potency value to be interpretable, record:

  • Material. Sequence, modifications, how the stock concentration was determined and the labware used.
  • Assay. Cell line or membrane source, readout, tracer and its Kd and concentration, incubation time and temperature, buffer, carrier protein and albumin content.
  • Analysis. Equation fitted, number of concentrations and replicates, any IC50-to-Ki conversion, and log-scale averages.

This guide describes general laboratory methods and published literature only. It is not a statement about the activity or behaviour of any particular material. Terms used here are defined in the glossary, and questions can be sent to support.

Terms used in this guide

Related tools and guides

References

  1. Neubig RR, Spedding M, Kenakin T, Christopoulos A. International Union of Pharmacology Committee on Receptor Nomenclature and Drug Classification. XXXVIII. Update on terms and symbols in quantitative pharmacology. Pharmacol Rev. 2003;55(4):597-606. PMID 14657418 · DOI
  2. Hulme EC, Trevethick MA. Ligand binding assays at equilibrium: validation and interpretation. Br J Pharmacol. 2010;161(6):1219-37. PMID 20132208 · DOI
  3. Pollard TD. A guide to simple and informative binding assays. Mol Biol Cell. 2010;21(23):4061-7. PMID 21115850 · DOI
  4. Cheng Y, Prusoff WH. Relationship between the inhibition constant (K1) and the concentration of inhibitor which causes 50 per cent inhibition (I50) of an enzymatic reaction. Biochem Pharmacol. 1973;22(23):3099-108. PMID 4202581 · DOI
  5. Sebaugh JL. Guidelines for accurate EC50/IC50 estimation. Pharm Stat. 2011;10(2):128-34. PMID 22328315 · DOI
  6. Black JW, Leff P. Operational models of pharmacological agonism. Proc R Soc Lond B Biol Sci. 1983;220(1219):141-62. PMID 6141562 · DOI
  7. Willard FS, Douros JD, Gabe MB, Showalter AD, Wainscott DB, Suter TM, et al. Tirzepatide is an imbalanced and biased dual GIP and GLP-1 receptor agonist. JCI Insight. 2020;5(17):e140532. PMID 32730231 · DOI

Cited literature is provided for scientific context only. Many of these reviews concern proteins or pharmaceutical development; they are cited for general chemistry and do not describe or endorse any use of these products.

For laboratory research use only. Not for human or veterinary use. This page is general chemistry education and does not describe or endorse any use of Sealed Peptides products. Cited literature is provided for scientific context only.

Guide FAQ

What is the difference between IC50 and Ki?

IC50 is the concentration of an unlabelled compound that reduces the binding of a labelled tracer by half under the conditions of one experiment, so it changes with the tracer concentration. Ki is the equilibrium dissociation constant of the compound itself. For simple competitive binding the two are linked by the Cheng-Prusoff equation, Ki = IC50 / (1 + [L]/Kd), where [L] and Kd are the tracer concentration and its dissociation constant.

What is the difference between EC50 and Kd?

Kd is a binding constant: the concentration at which half the receptors are occupied at equilibrium. EC50 is a functional value: the concentration that gives half the maximal response in a particular assay, such as cAMP production. Because cells can amplify the signal, EC50 is often lower than Kd, and it shifts with receptor expression level and the readout used.

How do I convert EC50 to pEC50?

pEC50 is the negative base-10 logarithm of the EC50 in mol/L. An EC50 of 1 nM (1 x 10^-9 M) is a pEC50 of 9.0, and 3 nM is about 8.52. A difference of one log unit is a ten-fold difference in potency, and averages of replicate experiments are usually taken on the log values.

Why do published potency values for the same peptide differ?

Potency depends on the cell line and its receptor density, the readout, incubation time, temperature, buffer composition (including albumin), how the concentration was determined and losses to labware. Values are most comparable when measured side by side in the same assay.

Is a lower IC50 better?

A lower IC50 means less compound was needed to reach half-maximal inhibition in that experiment, so the compound was more potent under those conditions. It does not by itself say anything about selectivity, maximal effect or behaviour in another assay, and because IC50 shifts with tracer concentration and assay setup, IC50 values are only directly comparable when they come from the same protocol. Ki, from the Cheng-Prusoff correction, is the better value to compare across binding experiments.

How do I convert IC50 to pIC50 or Ki to pKi?

Take the negative base-10 logarithm of the value in mol/L. An IC50 of 10 nM (1 x 10^-8 M) is a pIC50 of 8.0, 100 nM is 7.0 and 250 nM is about 6.60; a Ki of 2 nM is a pKi of about 8.70. Log values are the ones to average across repeat experiments, and a one-unit difference is a ten-fold difference in concentration.

Who is this guide written for?

Laboratory staff and researchers handling research-use-only materials. "Reading Peptide Receptor Assays: Kd, Ki, IC50 and EC50" covers laboratory practice only and describes no use of any product in people or animals.

Does Sealed Peptides give usage advice?

No. Our guides and calculators cover laboratory handling, analysis and unit arithmetic only. All products are sold for laboratory research use only.

Is there a calculator that goes with this guide?

Yes: Molarity calculator, ng/mL and µg/mL to nM converter, Dilution calculator. They run free in the browser with no signup.

How are lyophilized research peptides usually stored?

Lyophilized powders are generally kept sealed, dry, protected from light and frozen (around -20°C). Each product page lists its stated storage condition, and our peptide storage guide explains the reasoning.

More answers: Site FAQ · Storage guide · Storage reference tables

Explore Sealed Peptides

Coming soon: Epitalon · Thymosin Alpha-1 · Glutathione · ARA-290